Powdll Converter For Mac



  1. Powell Converter For Mac Download
  2. Powdll Converter For Mac Download

PowDLL is a.NET dynamic link library used for the interconversion procedure between variable formats of Powder X-Ray files. PowDLL Converter PowDLL Converter 2.2 PowDLL is a.NET dynamic link library used for the interconversion procedure between variable formats of Powder X-Ray files. The DLL is capable of handling the most common file formats (binary and ASCII).

VendorData FormatRequired Parameter FilesOptional Parameter Files
ACD/Labs*.spectrus, *.gnr, *.esp, *.txt, *.smp
Acorn NMR, Inc.*.fid, *.nmr, *.2d
Agilent (Varian)data, *.fdf, fid0001.fdf, *.txt, fid, phasefile, data* (VNMR, VnmrJ, SpinSight)acq, proc, procparacq_2, text
ASCIIa*.txt; *.prn, *.csv, *.asc
Bruker*.ser, *.rr, *.fid, *.1r, *.1i,
*.2rr, *.* (DISNMR, UXNMR, XWINNMR, WinNMR, TopSpin)
acqus, procs, acqu2, proc2s, *.fqs, *.fa1, *.fa2, *.fp1, *.fp2title, intrng, *.tit, *.ti2
Felix*.*
Galactic*.spc
Gaussian Output*.log, *.out
GE *.raw, *.* (Nicolet)
*.* (Omega)
JCAMP*.dx; *.jdx
JEOL Ltd.*.als, *.jdf, *.nmfid, *.nmf, *.bin, *.nmdata, *.nmd, *.gxd, *.* (Alpha, Generic, Delta, Lambda)*.gxp, *.hdrexp.param, exp.par
Lybrics*.*
Magritek*.1d; *.2d
MSI Felix*.*
Nanalysis*.dx
Nicolet*.dat
NUTS*.*
Oxford Instruments*.fid
QOneTec*.nmr
Tecmag*.tnt, *.* (MacNMR)
Thermo Scientifica *.spc
picoSpin (*.jdx)

a File export is also supported (in the case of JCAMP, for 1D NMR only).

VendorData FormatExtensionComments
ACD/LabsACD/Spectrus
ACD/SpecManager
*.spectrus, *.esp
SCIEXAnalyst*.wiff, *.wiff.scanSingle mass spectra, LC-MS and most LC-MSn imported. Splitter available. UV data not currently imported.
LightSight—Spectra are supported via export to NetCDF.
Analyst QS*.wiffSingle mass spectra, LC-MS and most LC-MSn imported. Splitter available.
Analyst TF*.wiff
Agilent1100 Series LC/MSD Quad and Ion Trap Systems*.ms, *.yepDAD data and single wavelength chromatograms. Splitter available.
ChemStation*.msSplitter available.
LC TOF*.wiff
MassHunter (6000 series)*.binEntire *.D folder should be used. Agilent component requires Microsoft .NET version 2. DAD can be imported and MS/MS split controlled.
OpenLab Rev. C.01.07, C.01.08, C.01.09*.DUV, LC-UV and LC-MS
Entire *.D folder should be used
*.ms, *.ch, *.uv
Applied BiosystemsMariner Data Explorer ASCII LC/MS*.txtLC-MS data only.
Bruker and Agilent Agilent or Bruker LC/MS Ion Trap*.yepLC-MS and DAD data.
BrukerCompass (accurate mass data)*.dEntire *.D folder should be used. Bruker component requires Microsoft .NET version 3.5. Possible issue noted for MaXis Impact data.
HitachiLIT–TOF*.datImport no longer supported
M–8000 and D–7000*.msd; *.dadLC-MS and DAD data.
JEOL (Japan)JEOL-DX*.jsp, *.jpf, *.jmcSingle mass spectra and chromatogram curves.
JEOL K9*.speLC(GC)-MS data.
JEOL XMS*.datGC-MS data.
LECO CorporationChromaTOF-HRT™ for Citius™ (LC) and Pegasus® (GC) HRTs*.smpGC/MS or LC/MS data; LC/MS with in-source CID provides separate precursor and fragment ion (isCID) channels; LECO GC-TOF MS data is supported.
Matlab/Eigenvector ResearchDSO format a*.matSingle mass spectra and LC(GC)-MS data.
National Institute of Standards and TechnologyNIST MS Software*.mspUses Lib2NIST to convert .msp to supported format (.hpj or .sdf).
NIST SDF Library*.sdfSplitter available.
PerkinElmerTOFData*.tofdata*
TOFData Centroid*.tofline
SCIEXPE SCIEX API to Piff*.~pi, *.~piff
Shimadzu CorporationLCMS-IT-TOF*.lcdLC-MS and LC-MSn data only. Requires vendor software on same computer.
GCMSsolution*.qgdGC-MS data
LCMSsolution*.qldDAD data and single wavelength chromatograms. May require vendor software on same computer.
LabSolutions*.lcd, *.qgdioModule supports QTOF data and TIC or SIM traces.
Thermo ScientificXcalibur*.rawData splitting by Scan Filter parameters is available.
Galactic*.spcExport is available for single MS only.
UnidatanetCDF*.cdf, *.ncSplitter available.
Varian1200*.datSplitter available.
XMS*.xms, *.smsSplitter available.
Saturn 2000*.smsSplitter available.
Waters CorporationMassLynx*.rawAll files in the folder containing the _functns.inf file are necessary for data import. Splitter available.
Micromass OpenLynx*.rptSplitter available
Millennium32 (2D and 3D PDA data)Import is no longer supported
Empower 2 and 3
(2D and 3D PDA data)
via Connect to1 or with help of ACD/Empower Add-on
Empower 2 and 3 (3D MS data)LC-MS data. via Connect to1 or with help of ACD/Empower Add-on
UNIFIvia Connect to1
Open SourceASCII a*.txtSingle MS only.
JCAMP a*.dx, *.jdxSplitter available.
mzML
netCDF a*.cdf, *.ncSingle MS and LC(GC)-MS data.

Powell Converter For Mac Download

a File export is also supported
1 Connect to utility requires vendor software on same computer. It doesn’t work in Citrix.

Mac
VendorData FormatExtensionComments
ACD/LabsACD/Spectrus
ACD/SpecManager
*.spectrus
*.esp
Matrix a*.txt
Open SourceASCII a*.txt; *.prn; *.csv; *.asc
Agilent1100 Series LC/MSD Quad and Ion Trap Systems*.ms, *.yepUV, LC-UV and LC-MS
ChemStation
Rev. B.02.01, B.03.01, B.04.01, B.04.02, B.04.03, C.01.04
*.DUV, LC-UV and LC-MS
Entire *.D folder should be used
*.ms, *.ch, *.uv
Open Lab C v.1.04*.DUV, LC-UV and LC-MS
Entire *.D folder should be used
*.ms, *.ch, *.uv
Open Lab Rev. C.01.07, C.01.08, C.01.09*.DUV, LC-UV and LC-MS
Entire *.D folder should be used
*.ms, *.ch, *.uv
EZChrom*.datUV traces only. Requires vendor software on same computer.
AB SCIEXAnalyst*.wiffLC-UV and LC-MS
Bruker and Agilent Agilent or Bruker LC/MS Ion Trap*.yepLC-UV and LC-MS
Bruker Compass
(accurate mass data)
*.DLC-MS, LC-UV, UV
Entire *.D folder should be used.
MATLABDSO a*.mat
PerkinElmer TotalChrom™*.rawImport was supported via Connect to2 until ACD/Labs products v. 2018
Pic Solution *.dat.csvLC traces
Shimadzu CorporationLCMS-IT-TOF*.lcdLC-MS and LC-UV1
Requires vendor software on same computer.
LCMSsolution*.qldLC-MS, LC-UV and UV traces
May require vendor software on same computer
Thermo ScientificAtlasPDA and DAD traces via Connect to2, or using an ACD/Atlas Add-on
Xcalibur*.rawLC-MS, LC-UV and UV traces
Chromeleon 6; 7UV and LC-UV, via Connect to2, or using an ACD/Chromeleon Add-on
Generalized Analytical Markup Language Hierarchy (GAML)*.gamlLC-UV and LC-MS data
UnidatanetCDF*.cdf, *.ncLC-MS, LC-UV and UV traces
Waters CorporationMassLynx*.rawLC-UV and LC-MS
Micromass OpenLynx*.rptLC-UV and LC-MS
Empower LCUV data *.arwLC-UV
Empower 2 and 3UV, LC-UV and LC-MS traces, via Connect to2 or using an ACD/Empower Add-on
UNIFIvia Connect to2

a File export is also supported.
1 To import *.lcd files from version 5.42SP2, vendor software should be installed on the same computer.
2 Connect to utility requires vendor software on same computer. It doesn’t work in Citrix.

VendorData FormatExtensionComments
ACD/LabsACD/Spectrus
ACD/SpecManager
*.spectrus, *.esp
AgilentHP 84552A*.wav
ChemStation a*.uv
Agilent (Varian)Cary UV*.b*; *.d*
ASCII single, dual and multicolumn*.txt; *.prn; *.csv; *.asc
BrukerOPUS*.*
DeltaNu*.spc
DionexChromeleon avia Connect to1 or using an ACD/Chromeleon Add-on
Foss NIRSystems*.da
JASCO CorporationJ-700*.jws
JCAMP, JCAMP multispectra*.dx; *.jdx
LabControl*.uvd; *.irs
MATLABDSO a*.mat
Ocean Optics*.*
PerkinElmer Instruments*.sp
Shimadzu CorporationIR*.irs
Thermo ScientificGalactic*.spc
Mattson*.*
Nicolet OMNIC*.spa; *.spg
Waters CorporationEmpower 2 and 3via Connect to1 or using an ACD/Empower Add-on
MassLynx*.inf

a Diode Array Detector (DAD) support for hyphenated data.
1 Connect to utility requires vendor software on same computer. It doesn’t work in Citrix.

VendorData Format
ACD/Labs*.spectrus, *.esp
ASCII single, dual and multi column*.txt; *.prn; *.csv; *.asc
Bruker DIFFRAC-AT*.raw
Bruker DIFFRAC-PLUS*.raw
Galactic*.spc
Gatan*.dm3
JCAMP,
JCAMP multispectra
*.dx;
*.jdx
PANalytical XRDML a
PowDLL b*.*
Sirius Analytical Instruments
STOE XRPD*.raw
TA Instruments*.*

a Older Philips X-Ray instrument data RD and UDF formats may be converted to the PANalytical XRDML formats with conversion software provided by PANalytical.
b NET converter for XRPD files.

VendorData Format
ACD/Labs*.sk2
Adobe Acrobat (output only)*.pdf
Symyx*.mol, *.sdf, *.rxn
ChemDraw*.chm, *.cdx
ISIS Sketch*.skc
InChI
SMILES
Chemical Markup Language (output only)*.cml
GIF image format*.gif
PNG image format*.png
JPG image format (input only)*.jpg
Windows Bitmap*.bmp, *.dib
Paintbrush (output only)*.pcx
TIFF Bitmap (output only)*.tif
HTML (output only)*.html
Windows Metafile*.wmf
ChemSketch 1.0 (input only)*.mst, *.rtp
  1. Some file formats require the installation of ChemBasic Goodies, a separate download and installation for freeware users
  2. You can still input structures from unsupported formats by opening the file with another program and pasting it into ACD/ChemSketch as an OLE object
Converter
VendorData Format
ASCIIa*.txt; *.prn, *.csv, *.asc
JCAMPa*.dx; *.jdx
Pistoia Alliance*.helm; *.xhelm
Unit converter for mac

a File export is also supported (in the case of JCAMP, for 1D NMR only)

Powell converter for mac os

At ACD/Labs we strive to support future analytical data format standardization efforts, such as AnIML.

Powdll Converter For Mac Download

ACD/Labs is a member of the Allotrope Partner Network participating in the creation of the Allotrope Framework. Support of the emerging Allotrope analytical data standard is a strategic development goal for ACD/Labs. Learn more here.